Volumetric
In X11 the SDL error "Unknown touch device" can occur after which the application stops recognizing touch events. For a kiosk-type application this results in a hang as far as the user is concerned. This is reproducible on HP Z220/Z230/Z240 workstations by swapping USB cables for a while and it also occurs with no physical changes, probably due to USB device power management. A workaround is to make SDL re-enumerate the touch devices like it does at startup. A patch is attached.
The internal function SDL_EGL_LoadLibrary() did not delete and remove a mostly
uninitialized data structure if loading the library first failed. A later try to
use EGL then skipped initialization and assumed it was previously successful
because the data structure now already existed. This led to at least one crash
in the internal function SDL_EGL_ChooseConfig() because a NULL pointer was
dereferenced to make a call to eglBindAPI().